| TECHNICAL DATA |
STORAGE SERIES |
| FEATURES |
FORCED DRAUGHT |
| SERIES |
GSG SECURGAS |
| MODEL |
80 |
120 |
| mounting system |
UNIT |
wall hanging |
| rated power with G20-natural gas |
kW |
5,0 |
5,0 |
| useful power with G20-natural gas |
kW |
4,7 |
4,7 |
| rated power with G300-G31-LPG |
kW |
5,0 |
5,0 |
| useful power with G300-G31-LPG |
kW |
4,7 |
4,7 |
| efficency |
% |
94 |
94 |
| utilizable gas |
G20-natural gas |
|
yes |
| G30-LPG |
|
yes |
| G31-LPG |
|
yes |
| consumption |
G20-natural gas |
m3/h |
0,53 |
0,53 |
| G30-LPG |
kg/h |
0,39 |
0,39 |
| G31-LPG |
kg/h |
0,37 |
0,37 |
| burner |
|
inox multigas |
| heating time Δt° 40 °C |
min |
40 |
61 |
| continous production at 40 °C* |
lt/h |
161 |
161 |
| temperature adjustment |
|
yes |
| gas safety valve |
|
yes |
| over-heating safety cut-off |
|
yes |
| hydraulic safety valve |
|
yes |
| smoke exaust safety thermostat (cut-off) |
|
yes |
| thermometer |
|
yes |
| piezo ignition |
|
automatic |
| maximum working pressure |
bar |
6 |
| tank material |
|
steel |
| protection of the tank against corrosion |
|
glass lined according to norm DIN 4753+replaceable magnesium anode |
| replaceable magnesium anode |
|
yes |
| thermal insulation |
|
injected polyurethane foam CFC free |
| connections |
hot water outlet |
inch |
Ø 1/2" M |
| cold water inlet |
inch |
Ø 1/2" M |
| recycle |
inch |
no |
| gas |
inch |
Ø 3/8" F |
| smoke exaust pipe diameter |
mm |
38 (air inlet 60) |
| heat |
m2 |
- |
| maximum length coaxial pipe |
m |
3 |
3 |
| tension/frequency/power |
V/Hz/W |
230-240/50/26 |
| package |
height |
cm |
110 |
147 |
| width |
cm |
54 |
54 |
| depth |
cm |
54 |
54 |
| weight |
net |
Kg |
49 |
74 |
| gross |
Kg |
53 |
78 |
| certificates |
|
 |
| * Cold water temperature reference 15 °C |